Data Portal @ linkeddatafragments.org

UGent Biblio

Search UGent Biblio by triple pattern

Matches in UGent Biblio for { ?s ?p Thermal ionization isotope dilution mass spectrometry (TI-IDMS) was used as an oligo-element method for the determination of Cr, Cd and Pb in photographic AgCl emulsions. After addition of an appropriate amount of isotopically enriched spikes (Cr-53, Cd-116 and Pb-206) to the solid samples, the latter were completely dissolved in NH, solution, permitting isotopic exchange to take place. Thereafter, AgCl was selectively removed by precipitation, whereby ultrasonic treatment was used to enhance the recovery of the elements of interest. Despite the use of concentrated HNO3 and H2O2 during further sample processing, preliminary experiments indicated the presence of a substantial remainder of the organic matrix (gelatine). Hence, the analytes of interest were isolated by means of electrolytic deposition on Pt electrodes. Subsequently, the deposits were dissolved from the Pt electrodes using a mixture of concentrated HNO3 and H2O2 and the solutions evaporated to dryness. The solid residues were taken up in diluted HNO3 and loaded onto Re filaments. In order to improve the ionization yield, prior to the sample, a silicagel suspension containing AlCl3 was loaded onto the filament and after sample loading, both H3BO3 (for Cr and Pb) and H3PO4 (for Cd and Pb) were added as further ionization aids. Finally, the isotope ratios of interest (Cr-52/Cr-53, Cd-114/Cd-116 and Pb-206/Pb-208) were determined using thermal ionization mass spectrometry, whereby all three analyte elements were vaporized from the same filament. The limits of detection obtained using this procedure range from 0.4 ng (for Cd) to 4 ng (for Pb). Four different AgCl emulsions were analyzed. For Cr, the concentration found was quite similar for all emulsions analyzed, as it varied between similar to 40 and similar to 100 ng/g only. For Cd, very low values were found for all samples analyzed (less than or equal to 3 ng/g). Finally, for Pb a much larger variation from similar to 10 ng/g up to similar to 5.5 mu g/g was observed. For the sample with the highest Pb content, an excellent agreement could be established between the results obtained using quadrupole-based ICP-IDMS and those using TI-IDMS. For the determination of Cr by means of quadrupole-based ICP-IDMS, an instrument equipped with a ShieldTorch system was used to avoid spectral overlap of the Cr-52(+) and (ArC+)-Ar-40-C-12 ion signals. Also in this case, the results obtained are in very good agreement with those obtained using TI-IDMS. The comparison between TI-IDMS and ICP-IDMS also made clear that sample inhomogeneity limits the between-sample precision attainable.. }

Showing items 1 to 1 of 1 with 100 items per page.