Matches in DBpedia 2014 for { <http://dbpedia.org/resource/Pacemaker_failure> ?p ?o. }
Showing items 1 to 35 of
35
with 100 items per page.
- Pacemaker_failure abstract "Pacemaker failure is the inability of an implanted artificial pacemaker to perform its intended function of regulating the beating of the heart. It is defined by the requirement of repeat surgical pacemaker-related procedure after the initial implantation. A study of pacemaker failure in Oregon in the 1970s indicates that 10% of implanted pacemakers failed within the first month. Causes of pacemaker failure included: lead related failure (lead migration, lead fracture, ventricular perforation), unit malfunction (battery failure or component malfunction), problems at the insertion site (infections, tissue breakdown, battery pack migration), failures related to exposure to high voltage electricity or high intensity microwaves, and a miscellaneous category (one patient had ventricular tachycardia when using his electric razor and another patient suffered from persistent pacing of the diaphragm muscle).".
- Pacemaker_failure icd10 "T82.1".
- Pacemaker_failure wikiPageID "24247569".
- Pacemaker_failure wikiPageRevisionID "602069528".
- Pacemaker_failure hasPhotoCollection Pacemaker_failure.
- Pacemaker_failure icd "T82.1".
- Pacemaker_failure name "Pacemaker failure".
- Pacemaker_failure subject Category:Cardiac_dysrhythmia.
- Pacemaker_failure subject Category:Embedded_systems.
- Pacemaker_failure subject Category:Implants.
- Pacemaker_failure subject Category:Prosthetics.
- Pacemaker_failure type Artifact100021939.
- Pacemaker_failure type Corrective103111899.
- Pacemaker_failure type Device103183080.
- Pacemaker_failure type EmbeddedSystems.
- Pacemaker_failure type Implant103563710.
- Pacemaker_failure type Implants.
- Pacemaker_failure type Instrumentality103575240.
- Pacemaker_failure type Object100002684.
- Pacemaker_failure type PhysicalEntity100001930.
- Pacemaker_failure type Prosthesis104013729.
- Pacemaker_failure type System104377057.
- Pacemaker_failure type Whole100003553.
- Pacemaker_failure type Disease.
- Pacemaker_failure type AilmentCondition.
- Pacemaker_failure type Situation.
- Pacemaker_failure comment "Pacemaker failure is the inability of an implanted artificial pacemaker to perform its intended function of regulating the beating of the heart. It is defined by the requirement of repeat surgical pacemaker-related procedure after the initial implantation. A study of pacemaker failure in Oregon in the 1970s indicates that 10% of implanted pacemakers failed within the first month.".
- Pacemaker_failure label "Pacemaker failure".
- Pacemaker_failure sameAs m.07s9vp4.
- Pacemaker_failure sameAs Q17004153.
- Pacemaker_failure sameAs Q17004153.
- Pacemaker_failure sameAs Pacemaker_failure.
- Pacemaker_failure wasDerivedFrom Pacemaker_failure?oldid=602069528.
- Pacemaker_failure isPrimaryTopicOf Pacemaker_failure.
- Pacemaker_failure name "Pacemaker failure".