Matches in Ghent University Academic Bibliography for { <https://biblio.ugent.be/publication/01GQFV9S3M3EQD7HEN7A37YW6S> ?p ?o. }
Showing items 1 to 23 of
23
with 100 items per page.
- 01GQFV9S3M3EQD7HEN7A37YW6S classification A1.
- 01GQFV9S3M3EQD7HEN7A37YW6S date "2022".
- 01GQFV9S3M3EQD7HEN7A37YW6S language "eng".
- 01GQFV9S3M3EQD7HEN7A37YW6S type journalArticle.
- 01GQFV9S3M3EQD7HEN7A37YW6S hasPart 01GQFVFYP6RMM25SFRQE087Q6N.pdf.
- 01GQFV9S3M3EQD7HEN7A37YW6S subject "Medicine and Health Sciences".
- 01GQFV9S3M3EQD7HEN7A37YW6S subject "Technology and Engineering".
- 01GQFV9S3M3EQD7HEN7A37YW6S doi "10.3390/jcm11102882".
- 01GQFV9S3M3EQD7HEN7A37YW6S issn "2077-0383".
- 01GQFV9S3M3EQD7HEN7A37YW6S issue "10".
- 01GQFV9S3M3EQD7HEN7A37YW6S volume "11".
- 01GQFV9S3M3EQD7HEN7A37YW6S abstract "Objective: Information about full-digital protocols for bite registration with intraoral scanners on multiple implants in the edentulous jaw is scarce. The purpose of this comparative in vivo study was to investigate the reliability and time efficiency of a novel full-digital bite registration technique for the manufacture of full-arch maxillary fixed implant prostheses. Material and methods: In ten patients, a full-arch maxillary fixed implant prosthesis was manufactured on multi-unit abutment level through an analog prosthetic workflow. The bite registration was performed with use of a screw-retained polymethyl methacrylate (PMMA) verification jig with detachable wax rim. To articulate the definitive edentulous maxillary implant cast in centric relation at the appropriate occlusal vertical dimension (OVD) to the mandibular antagonist cast, a type II articulator (Artex, Amann Girrbach) was used. Three to six months later, a full-digital bite registration was performed with use of dual-function scan bodies and bilateral connected bite pillars. The bite pillars screwed into the scan bodies were used to adjust and articulate the edentulous maxillary implant arch to the mandibular antagonist arch at the defined OVD. Treatment time for analog and digital bite registration technique was measured in each patient. The reliability of the digital bite registration technique was evaluated by 3D comparison of two sets of stereo lithographic (STL) files obtained from each patient. The three-dimensional deviation was defined along the X-, Y- and Z-axes (Geomagic Control X, 3D Systems Inc., Rock Hill, SC, USA). Results: The treatment time for digital bite registration using dual-function scan bodies and bite pillars was significantly shorter than analog bite registration with verification jig and wax rim (60.30%, SD 5.72%). Minor differences between the two techniques were observed with a linear deviation range of 1115 mu m (SD 668 mu m) overall, 46.2 mu m (SD 731.3 mu m) along the X-axis, -200.3 mu m (SD 744.3 mu m) along the Y-axis and 67.1 mu m (SD 752.2 mu m) along the Z-axis. Bilateral balanced contacts were registered in all patients during full-digital bite registration. Conclusions: The novel digital bite registration technique with dual-function scan bodies and bite pillars allows for a full-digital workflow for full-arch implant supported restorations. The digital bite workflow was 60% faster, and the overall deviation was around 1 mm, which can be considered clinically acceptable.".
- 01GQFV9S3M3EQD7HEN7A37YW6S author 00FEDBE4-F0EE-11E1-A9DE-61C894A0A6B4.
- 01GQFV9S3M3EQD7HEN7A37YW6S author 39BE00AE-F0EE-11E1-A9DE-61C894A0A6B4.
- 01GQFV9S3M3EQD7HEN7A37YW6S author urn:uuid:7b6b2edd-16a9-49cd-bed1-eef2e16cc5a3.
- 01GQFV9S3M3EQD7HEN7A37YW6S dateCreated "2023-01-23T17:37:32Z".
- 01GQFV9S3M3EQD7HEN7A37YW6S dateModified "2024-07-09T14:33:41Z".
- 01GQFV9S3M3EQD7HEN7A37YW6S name "Reliability and time efficiency of digital vs. analog bite registration technique for the manufacture of full-arch fixed implant prostheses".
- 01GQFV9S3M3EQD7HEN7A37YW6S pagination urn:uuid:7ad16112-6dc8-48db-b11e-e2edd5b37d1c.
- 01GQFV9S3M3EQD7HEN7A37YW6S publisher urn:uuid:7aecf6ee-91b3-4fd7-b579-ccb06c85925e.
- 01GQFV9S3M3EQD7HEN7A37YW6S sameAs LU-01GQFV9S3M3EQD7HEN7A37YW6S.
- 01GQFV9S3M3EQD7HEN7A37YW6S sourceOrganization urn:uuid:10f47338-7cf6-4e5f-b5de-670e23b70f07.
- 01GQFV9S3M3EQD7HEN7A37YW6S type A1.