Matches in UGent Biblio for { <https://biblio.ugent.be/publication/1201728#aggregation> ?p ?o. }
Showing items 1 to 35 of
35
with 100 items per page.
- aggregation classification "A1".
- aggregation creator B216638.
- aggregation creator B216639.
- aggregation creator person.
- aggregation creator person.
- aggregation creator person.
- aggregation date "2011".
- aggregation format "application/pdf".
- aggregation hasFormat 1201728.bibtex.
- aggregation hasFormat 1201728.csv.
- aggregation hasFormat 1201728.dc.
- aggregation hasFormat 1201728.didl.
- aggregation hasFormat 1201728.doc.
- aggregation hasFormat 1201728.json.
- aggregation hasFormat 1201728.mets.
- aggregation hasFormat 1201728.mods.
- aggregation hasFormat 1201728.rdf.
- aggregation hasFormat 1201728.ris.
- aggregation hasFormat 1201728.txt.
- aggregation hasFormat 1201728.xls.
- aggregation hasFormat 1201728.yaml.
- aggregation isPartOf urn:issn:0022-3727.
- aggregation language "eng".
- aggregation rights "I have transferred the copyright for this publication to the publisher".
- aggregation subject "Physics and Astronomy".
- aggregation title "Angular-resolved energy flux measurements of a dc- and HIPIMS-powered rotating cylindrical magnetron in reactive and non-reactive atmosphere".
- aggregation abstract "A rotating cylindrical magnetron equipped with a titanium target was sputtered in dc and in HIPIMS mode, both in metallic and in the oxide regime. For all sputter modes, the same process conditions and the same average sputtering power of 300 W were used. An angular-resolved study was performed, 90 degrees around the rotating cylindrical magnetron, which obtained the total energy flux arriving at the substrate. Furthermore, the energy flux per adparticle was calculated by measuring the deposition rate for all sputter modes and regimes. There is only a small difference in total arriving energy flux between the dc mode and the HIPIMS mode. A maximum arriving energy flux of ca 0.26 mW cm(-2) was measured, when normalized to the sputtering power. Concerning the deposition rate, up to a 75% decrease was found from dc to HIPIMS mode. Furthermore, the emission and the transport of the particles have a similar angular profile for all sputter modes. Among the HIPIMS modes, a decrease in deposition rate was measured with increasing pulse length. Therefore, the energy which arrives per adparticle is the highest for the HIPIMS modes. A difference in the angular shape of the energy per arriving adparticle is noticed between the dc and the HIPIMS modes. The dc mode has a maximum arriving energy per adparticle at around 50 degrees, while this is at 60 degrees for the HIPIMS mode.".
- aggregation authorList BK478243.
- aggregation issue "11".
- aggregation volume "44".
- aggregation aggregates 1201735.
- aggregation aggregates 1211464.
- aggregation isDescribedBy 1201728.
- aggregation similarTo 115201.
- aggregation similarTo LU-1201728.