Matches in UGent Biblio for { <https://biblio.ugent.be/publication/4387854#aggregation> ?p ?o. }
Showing items 1 to 37 of
37
with 100 items per page.
- aggregation classification "A1".
- aggregation creator B764938.
- aggregation creator B764939.
- aggregation creator B764940.
- aggregation creator B764941.
- aggregation creator B764942.
- aggregation creator person.
- aggregation date "2014".
- aggregation format "application/pdf".
- aggregation hasFormat 4387854.bibtex.
- aggregation hasFormat 4387854.csv.
- aggregation hasFormat 4387854.dc.
- aggregation hasFormat 4387854.didl.
- aggregation hasFormat 4387854.doc.
- aggregation hasFormat 4387854.json.
- aggregation hasFormat 4387854.mets.
- aggregation hasFormat 4387854.mods.
- aggregation hasFormat 4387854.rdf.
- aggregation hasFormat 4387854.ris.
- aggregation hasFormat 4387854.txt.
- aggregation hasFormat 4387854.xls.
- aggregation hasFormat 4387854.yaml.
- aggregation isPartOf urn:issn:0168-9002.
- aggregation language "eng".
- aggregation publisher "Elsevier".
- aggregation rights "I have transferred the copyright for this publication to the publisher".
- aggregation subject "Physics and Astronomy".
- aggregation title "Characterization of a cubic EJ-309 liquid scintillator detector".
- aggregation abstract "A cubic EJ-309 liquid scintillator of 10 cm width has been characterized for its response to gamma-rays and neutrons. Response functions to gamma-rays were measured with calibrated radionuclide gamma-ray sources in the energy range from 400 keV to 6 MeV. Response functions for neutrons were obtained from measurements at the PTB Van der Graaff accelerator with quasi-monoenergetic neutron beams in the energy range from 500 keV to 2.7 MeV, and at the PTB cyclotron with time-of-flight measurements in the energy range from 2.5 to 14 MeV. The light output and resolution function for electrons and protons were derived by a least squares adjustment to experimental data using theoretical response functions determined by Monte Carlo simulations. The simulated response function for neutron was validated by results of measurements with an AmBe neutron source which was characterized for its total neutron intensity. The results indicate that the cubic EJ-309 detector is suitable for use in mixed gamma-ray and neutron fields.".
- aggregation authorList BK1134404.
- aggregation endPage "54".
- aggregation startPage "45".
- aggregation volume "756".
- aggregation aggregates 4387855.
- aggregation isDescribedBy 4387854.
- aggregation similarTo j.nima.2014.03.028.
- aggregation similarTo LU-4387854.