Matches in UGent Biblio for { <https://biblio.ugent.be/publication/5830900#aggregation> ?p ?o. }
Showing items 1 to 36 of
36
with 100 items per page.
- aggregation classification "A1".
- aggregation creator B1016412.
- aggregation creator B1016413.
- aggregation creator B1016414.
- aggregation creator B1016415.
- aggregation creator B1016416.
- aggregation creator person.
- aggregation date "2014".
- aggregation format "application/pdf".
- aggregation hasFormat 5830900.bibtex.
- aggregation hasFormat 5830900.csv.
- aggregation hasFormat 5830900.dc.
- aggregation hasFormat 5830900.didl.
- aggregation hasFormat 5830900.doc.
- aggregation hasFormat 5830900.json.
- aggregation hasFormat 5830900.mets.
- aggregation hasFormat 5830900.mods.
- aggregation hasFormat 5830900.rdf.
- aggregation hasFormat 5830900.ris.
- aggregation hasFormat 5830900.txt.
- aggregation hasFormat 5830900.xls.
- aggregation hasFormat 5830900.yaml.
- aggregation isPartOf urn:issn:0039-128X.
- aggregation language "eng".
- aggregation rights "I have transferred the copyright for this publication to the publisher".
- aggregation subject "Medicine and Health Sciences".
- aggregation title "High variability in serum estradiol measurements in men and women".
- aggregation abstract "To reduce the variability in estradiol (E2) testing and to assure better patient care, standardization of E2 measurements has been recommended. This study aims to assess the accuracy and variability of E2 measurements performed by 11 routine immunological methods and 6 mass spectrometry methods using single donor serum materials and to compare the results to a reference method. The contribution of calibration bias, specificity or matrix effects, and imprecision on the overall variability of individual assays was evaluated. This study showed substantial variability in serum E2 measurements in samples from men and pre- and post-menopausal women. The mean bias across all samples, for each participant, ranged between -2.4% and 235%, with 3 participants having a mean bias of over 100%. The data suggest that calibration bias is the major contributor to the overall variability for nine assays. The analytical performances of most assays measuring E2 concentrations do not meet current needs in research and patient care. Three out of 17 assays would meet performance criteria derived from biological variability of +/- 12.5% bias at concentrations >= 20 pg/mL, and a maximum allowable bias of +/- 2.5 pg/mL at concentrations <20 pg/mL. The sensitivity differs highly between assays. Most assays are not able to measure E2 levels below 10 pg/mL. Standardization, specifically calibration to a common standard by using panels of individual patient samples, can reduce the observed variability and improve the utility of E2 levels in clinical settings.".