Matches in UGent Biblio for { <https://biblio.ugent.be/publication/855783#aggregation> ?p ?o. }
Showing items 1 to 37 of
37
with 100 items per page.
- aggregation classification "A1".
- aggregation creator B384495.
- aggregation creator B384496.
- aggregation creator B384497.
- aggregation creator person.
- aggregation creator person.
- aggregation creator person.
- aggregation date "2010".
- aggregation format "application/pdf".
- aggregation hasFormat 855783.bibtex.
- aggregation hasFormat 855783.csv.
- aggregation hasFormat 855783.dc.
- aggregation hasFormat 855783.didl.
- aggregation hasFormat 855783.doc.
- aggregation hasFormat 855783.json.
- aggregation hasFormat 855783.mets.
- aggregation hasFormat 855783.mods.
- aggregation hasFormat 855783.rdf.
- aggregation hasFormat 855783.ris.
- aggregation hasFormat 855783.txt.
- aggregation hasFormat 855783.xls.
- aggregation hasFormat 855783.yaml.
- aggregation isPartOf urn:issn:1618-2642.
- aggregation language "eng".
- aggregation rights "I have transferred the copyright for this publication to the publisher".
- aggregation subject "Earth and Environmental Sciences".
- aggregation title "Trace analysis of antidepressants in environmental waters by molecularly imprinted polymer-based solid-phase extraction followed by ultra-performance liquid chromatography coupled to triple quadrupole mass spectrometry".
- aggregation abstract "This paper presents the development, optimization, and validation of an innovative method to analyze trace concentrations of seven selected psychoactive pharmaceuticals in environmental waters. Hereby, the solid-phase extraction (SPE) potential of molecularly imprinted polymers (MIPs) in terms of extraction recovery, breakthrough, precision, and selectivity is studied for the first time. Instrumental analysis by ultra-performance liquid chromatography coupled to triple quadrupole mass spectrometry allowed a rapid (run time = 7.5 min) and sensitive (instrumental detection limit a parts per thousand currency sign7 pg injected) quantification of the target analytes. A systematic optimization study revealed that, among the seven compounds of interest, mainly the selective serotonin reuptake inhibitors paroxetine, fluoxetine, and citalopram are selectively retained on the MIPs. Experiments performed in spiked river water, sewage treatment plant (STP) effluent and influent showed for these compounds extraction recoveries higher than 70%, breakthrough volumes up to 200 mL, method detection limits (MDL) as low as 0.5 ng/L, and good precision (exemplified by relative standard deviations better than 15%, n a parts per thousand yenaEuro parts per thousand 3). Compared to the widely used hydrophilic-lipophilic balanced (HLB) polymers, the newly developed MIPs indicated to be more resistant toward matrix effects induced ion signal suppression particularly when dealing with relative dirty samples like STP influents. As a result of the better selectivity, the MDL obtained with the MIP-based SPE method was up to a factor of 7 lower compared to those obtained with a recently reported multi-residue HLB method. However, optimizing a HLB method in terms of selectivity, e.g., by introducing a stronger washing protocol, can significantly reduce its MDL up to values approximating those obtained with MIPs.".
- aggregation authorList BK695159.
- aggregation endPage "837".
- aggregation issue "2".
- aggregation startPage "825".
- aggregation volume "396".
- aggregation aggregates 868247.
- aggregation isDescribedBy 855783.
- aggregation similarTo s00216-009-3270-2.
- aggregation similarTo LU-855783.