Matches in DBpedia 2014 for { <http://dbpedia.org/resource/Fluorescent_microthermography> ?p ?o. }
Showing items 1 to 26 of
26
with 100 items per page.
- Fluorescent_microthermography abstract "Fluorescent microthermography (FMT) is a microscopy technique for infrared imaging of temperature distribution in small scale; the achievable spatial resolution is half micrometer and temperature resolution of 0.005 K. Time-dependent measurements are possible, as the fluorescence lifetime is only about 200 microseconds.A thin film of a phosphor, europium thenoyl-trifluoroacetonate, is applied on the surface (e.g. an integrated circuit die) and illuminated by ultraviolet light at 340-380 nm, stimulating fluorescence at mainly 612 nm line. The quantum efficiency of fluorescence decreases exponentially with temperature, differences in emitted light intensity can be therefore used to assess differences on surface temperature, with hot areas showing as darker.".
- Fluorescent_microthermography wikiPageID "26637474".
- Fluorescent_microthermography wikiPageRevisionID "351140697".
- Fluorescent_microthermography hasPhotoCollection Fluorescent_microthermography.
- Fluorescent_microthermography subject Category:Infrared_imaging.
- Fluorescent_microthermography subject Category:Measurement.
- Fluorescent_microthermography subject Category:Microscopy.
- Fluorescent_microthermography subject Category:Thermometers.
- Fluorescent_microthermography type Artifact100021939.
- Fluorescent_microthermography type Device103183080.
- Fluorescent_microthermography type Instrument103574816.
- Fluorescent_microthermography type Instrumentality103575240.
- Fluorescent_microthermography type MeasuringInstrument103733925.
- Fluorescent_microthermography type Object100002684.
- Fluorescent_microthermography type PhysicalEntity100001930.
- Fluorescent_microthermography type Thermometer104421872.
- Fluorescent_microthermography type Thermometers.
- Fluorescent_microthermography type Whole100003553.
- Fluorescent_microthermography comment "Fluorescent microthermography (FMT) is a microscopy technique for infrared imaging of temperature distribution in small scale; the achievable spatial resolution is half micrometer and temperature resolution of 0.005 K. Time-dependent measurements are possible, as the fluorescence lifetime is only about 200 microseconds.A thin film of a phosphor, europium thenoyl-trifluoroacetonate, is applied on the surface (e.g.".
- Fluorescent_microthermography label "Fluorescent microthermography".
- Fluorescent_microthermography sameAs m.0bh951_.
- Fluorescent_microthermography sameAs Q5462832.
- Fluorescent_microthermography sameAs Q5462832.
- Fluorescent_microthermography sameAs Fluorescent_microthermography.
- Fluorescent_microthermography wasDerivedFrom Fluorescent_microthermography?oldid=351140697.
- Fluorescent_microthermography isPrimaryTopicOf Fluorescent_microthermography.