Matches in DBpedia 2014 for { <http://dbpedia.org/resource/Lippmann_electrometer> ?p ?o. }
Showing items 1 to 31 of
31
with 100 items per page.
- Lippmann_electrometer abstract "A Lippmann electrometer is a device for detecting small rushes of electric current and was invented by Gabriel Lippmann in 1873.The device consists of a tube which is thick on one end and very thin on the other. The thin end is designed to act as a capillary tube. The tube is half-filled with mercury with a small amount of dilute sulfuric acid above the mercury in the capillary tube. Metal wires are connected at the thick end into the mercury and at the thin end into the sulfuric acid.When the pulse of electricity arrives it changes the surface tension of the mercury and allows it to leap up a short distance in the capillary tube. This device was used in the first practical ECG machine which was invented by Augustus Desiré Waller.".
- Lippmann_electrometer thumbnail Kapillarelektrometer.jpg?width=300.
- Lippmann_electrometer wikiPageID "6316384".
- Lippmann_electrometer wikiPageRevisionID "553341863".
- Lippmann_electrometer hasPhotoCollection Lippmann_electrometer.
- Lippmann_electrometer subject Category:Electrophysiology.
- Lippmann_electrometer subject Category:Measuring_instruments.
- Lippmann_electrometer type Artifact100021939.
- Lippmann_electrometer type Device103183080.
- Lippmann_electrometer type Instrument103574816.
- Lippmann_electrometer type Instrumentality103575240.
- Lippmann_electrometer type MeasuringInstrument103733925.
- Lippmann_electrometer type MeasuringInstruments.
- Lippmann_electrometer type Object100002684.
- Lippmann_electrometer type PhysicalEntity100001930.
- Lippmann_electrometer type Whole100003553.
- Lippmann_electrometer comment "A Lippmann electrometer is a device for detecting small rushes of electric current and was invented by Gabriel Lippmann in 1873.The device consists of a tube which is thick on one end and very thin on the other. The thin end is designed to act as a capillary tube. The tube is half-filled with mercury with a small amount of dilute sulfuric acid above the mercury in the capillary tube.".
- Lippmann_electrometer label "Capillaire elektrometer".
- Lippmann_electrometer label "Elettrometro di Lippmann".
- Lippmann_electrometer label "Kapillarelektrometer".
- Lippmann_electrometer label "Lippmann electrometer".
- Lippmann_electrometer sameAs Kapillarelektrometer.
- Lippmann_electrometer sameAs Elettrometro_di_Lippmann.
- Lippmann_electrometer sameAs Capillaire_elektrometer.
- Lippmann_electrometer sameAs m.0g0qxy.
- Lippmann_electrometer sameAs Q883023.
- Lippmann_electrometer sameAs Q883023.
- Lippmann_electrometer sameAs Lippmann_electrometer.
- Lippmann_electrometer wasDerivedFrom Lippmann_electrometer?oldid=553341863.
- Lippmann_electrometer depiction Kapillarelektrometer.jpg.
- Lippmann_electrometer isPrimaryTopicOf Lippmann_electrometer.