- Munnerlyn_Formula abstract "The Munnerlyn Formula is the theoretical formula discovered by Charles Munnerlyn, which gives the depth an excimer laser will need to ablate during LASIK surgery or similar medical interventions. The formula states that the depth of the ablation (in micrometres) per diopter of refractive change is equal to the square of the diameter of the optical ablation zone measured in millimeters, divided by three. For example, to change refraction by 4 diopters with an optical zone of 3 mm would require ablation of 12 micrometeres. As the depth of ablation is proportional to the square of the opitcal zone, changing the refraction by 4 diopters but with an optical zone of 6 mm would require a much deeper ablation of approximately 48 micrometers. The ablation depth does not include the transition zone of the surgery.The actual ablation depth and surface shape will be slightly different from the theoretical Munnerlyn formula. Many factors must be taken into account at the time of the surgery. The sex, age, and race of the patient, and such things as the barometric pressure and ambient humidity will change slightly the required ablation.The formula was derived based on creating a theoretical lenticular surface in a polymethylmethacrylate (PMMA) model, and modified by testing on in vivo animal tissue.".
- Munnerlyn_Formula wikiPageID "26008484".
- Munnerlyn_Formula wikiPageRevisionID "596904515".
- Munnerlyn_Formula hasPhotoCollection Munnerlyn_Formula.
- Munnerlyn_Formula subject Category:Lasers.
- Munnerlyn_Formula type Artifact100021939.
- Munnerlyn_Formula type Device103183080.
- Munnerlyn_Formula type Instrumentality103575240.
- Munnerlyn_Formula type Laser103643253.
- Munnerlyn_Formula type Lasers.
- Munnerlyn_Formula type Object100002684.
- Munnerlyn_Formula type OpticalDevice103851341.
- Munnerlyn_Formula type PhysicalEntity100001930.
- Munnerlyn_Formula type Whole100003553.
- Munnerlyn_Formula comment "The Munnerlyn Formula is the theoretical formula discovered by Charles Munnerlyn, which gives the depth an excimer laser will need to ablate during LASIK surgery or similar medical interventions. The formula states that the depth of the ablation (in micrometres) per diopter of refractive change is equal to the square of the diameter of the optical ablation zone measured in millimeters, divided by three.".
- Munnerlyn_Formula label "Munnerlyn Formula".
- Munnerlyn_Formula sameAs m.0b6hbvx.
- Munnerlyn_Formula sameAs Q6936792.
- Munnerlyn_Formula sameAs Q6936792.
- Munnerlyn_Formula sameAs Munnerlyn_Formula.
- Munnerlyn_Formula wasDerivedFrom Munnerlyn_Formula?oldid=596904515.
- Munnerlyn_Formula isPrimaryTopicOf Munnerlyn_Formula.