- Murray_loop_bridge abstract "Murray loop bridge is a bridge circuit used for locating faults in underground or underwater cables. It has been used for more than 100 years. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted. The bridge is brought to balance by changing the values of RB1 and RB2, which is achieved when:which is equivalent to:The value of resistance Rx is proportional the length Lx, thus the location of the fault can be calculated:where L is the total length of the cable under test - a value proportional to Rg.The method assumes a single fault exists, of low resistance compared with the undamaged cable insulation resistance, and that the cable conductors have uniform resistance per unit length.".
- Murray_loop_bridge thumbnail Murray_loop_bridge.svg?width=300.
- Murray_loop_bridge wikiPageID "20294668".
- Murray_loop_bridge wikiPageRevisionID "604792167".
- Murray_loop_bridge hasPhotoCollection Murray_loop_bridge.
- Murray_loop_bridge subject Category:Electrical_circuits.
- Murray_loop_bridge subject Category:Measuring_instruments.
- Murray_loop_bridge type Artifact100021939.
- Murray_loop_bridge type Circuit103033362.
- Murray_loop_bridge type Device103183080.
- Murray_loop_bridge type ElectricalCircuits.
- Murray_loop_bridge type ElectricalDevice103269401.
- Murray_loop_bridge type Instrument103574816.
- Murray_loop_bridge type Instrumentality103575240.
- Murray_loop_bridge type MeasuringInstrument103733925.
- Murray_loop_bridge type MeasuringInstruments.
- Murray_loop_bridge type Object100002684.
- Murray_loop_bridge type PhysicalEntity100001930.
- Murray_loop_bridge type Whole100003553.
- Murray_loop_bridge comment "Murray loop bridge is a bridge circuit used for locating faults in underground or underwater cables. It has been used for more than 100 years. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted.".
- Murray_loop_bridge label "Murray loop bridge".
- Murray_loop_bridge sameAs m.04zzlnb.
- Murray_loop_bridge sameAs Q6939533.
- Murray_loop_bridge sameAs Q6939533.
- Murray_loop_bridge sameAs Murray_loop_bridge.
- Murray_loop_bridge wasDerivedFrom Murray_loop_bridge?oldid=604792167.
- Murray_loop_bridge depiction Murray_loop_bridge.svg.
- Murray_loop_bridge isPrimaryTopicOf Murray_loop_bridge.