Matches in DBpedia 2014 for { <http://dbpedia.org/resource/SwePol> ?p ?o. }
Showing items 1 to 66 of
66
with 100 items per page.
- SwePol abstract "SwePol is a 254.05-kilometre (157.86 mi)-long monopolar high-voltage direct current (HVDC) submarine cable between the Stärnö peninsula near Karlshamn, Sweden, and Bruskowo Wielkie, near Słupsk, Poland.SwePol is a high voltage cable with a cross section of 2,100 square millimetres (3.3 sq in). It runs for 222 kilometres (138 mi) as underground cable from Stärno HVDC Station to the shore of the Baltic Sea. The 239.28 kilometres (148.68 mi) long submarine cable comes ashore in Poland near Ustka at 54°34′25″N 16°46′57″E and runs underground for the remaining 12.55 kilometres (7.80 mi) to Bruskowo Wielkie HVDC Static Inverter Plant.Unlike other monopolar HVDC schemes, Swepol uses a metallic return consisting of 2 cables with 630 square millimetres (0.98 sq in) sections for the submarine portion of the line, and a single cable with 1,100 square millimetres (1.7 sq in) sections for the land portions.Both stations use air-core inductance smoothing rectifiers of 225 mH and a weight of 27.5 tonnes, with filters for the 11th, 13th, 24th, and 36th harmonics. Each filter consists of a coil and a capacitor switched in row. The filters for the 11th and 13th harmonics are adjustable. The filters deliver a reactive power of 95 Mvar. Additional 95 Mvar reactive power is delivered by a capacitor bank. Each station's static inverter, which is switched as a 12-pulse thyristor bridge, consists of 792 thyristors arranged in three 16 metres (52 ft) high towers installed in a valve hall.The SwePol link was inaugurated in 2000 and can transmit up to 600 MW power at a voltage of 450 kV. It is owned and maintained by SwePol Link AB, a company jointly owned by the state-owned Swedish power company Svenska Kraftnät (51%), Vattenfall (16%), and Polish transmission system operator PSE-Operator (33%).Since coming online, 11 instances of cable damage have occurred: one on the high voltage line and 10 on the return cable. Causes have included ship anchors, fishing nets, fire, and grid power disturbances. On February 14, 2005, the smoothing reactor at the HVDC station at Bruskowo Wielkie was destroyed by fire. Repairs took 20 hours.".
- SwePol wikiPageExternalLink default.aspx?crs=EPSG%3A2180&bbox=362727,739923,364049,739237&variant=TOPO.
- SwePol wikiPageExternalLink swepollinkbruskowowielkie.futbolowo.pl.
- SwePol wikiPageExternalLink c84945b54aa6cfb8c125774a00486402.aspx.
- SwePol wikiPageExternalLink indexe.html.
- SwePol wikiPageExternalLink www.swepollink.se.
- SwePol wikiPageID "1643127".
- SwePol wikiPageRevisionID "593476546".
- SwePol acVoltage "400.0".
- SwePol cableManufacturer ABB_Group.
- SwePol capacity "600.0".
- SwePol country Poland.
- SwePol country Sweden.
- SwePol currentType "HVDC".
- SwePol dcVoltage "450.0".
- SwePol direction "north–south".
- SwePol est "2000".
- SwePol finish "Bruskowo Wielkie Static Inverter Plant, Poland".
- SwePol hasPhotoCollection SwePol.
- SwePol lengthKm "254".
- SwePol mapCaption "Location of SwePol".
- SwePol name "SwePol".
- SwePol owner "SwePol Link AB".
- SwePol partners PSE-Operator.
- SwePol partners Svenska_Kraftnät.
- SwePol partners Vattenfall.
- SwePol start "Stärnö Static Inverter Plant, Sweden".
- SwePol substationManufacturer ABB_Group.
- SwePol through Baltic_Sea.
- SwePol type "subsea cable".
- SwePol subject Category:Connections_across_the_Baltic_Sea.
- SwePol subject Category:Electric_power_infrastructure_in_Poland.
- SwePol subject Category:Electric_power_infrastructure_in_Sweden.
- SwePol subject Category:Energy_infrastructure_completed_in_2000.
- SwePol subject Category:HVDC_transmission_lines.
- SwePol subject Category:Poland–Sweden_relations.
- SwePol subject Category:Submarine_power_cables.
- SwePol point "54.50211111111111 16.891222222222222".
- SwePol type Artifact100021939.
- SwePol type Cable102934168.
- SwePol type Conductor103088707.
- SwePol type Device103183080.
- SwePol type HVDCTransmissionLines.
- SwePol type Instrumentality103575240.
- SwePol type Object100002684.
- SwePol type PhysicalEntity100001930.
- SwePol type PowerLine103995535.
- SwePol type SubmarinePowerCables.
- SwePol type Whole100003553.
- SwePol type SpatialThing.
- SwePol comment "SwePol is a 254.05-kilometre (157.86 mi)-long monopolar high-voltage direct current (HVDC) submarine cable between the Stärnö peninsula near Karlshamn, Sweden, and Bruskowo Wielkie, near Słupsk, Poland.SwePol is a high voltage cable with a cross section of 2,100 square millimetres (3.3 sq in). It runs for 222 kilometres (138 mi) as underground cable from Stärno HVDC Station to the shore of the Baltic Sea.".
- SwePol label "SwePol Link".
- SwePol label "SwePol".
- SwePol label "SwePol".
- SwePol label "Swepol".
- SwePol sameAs Swepol.
- SwePol sameAs SwePol.
- SwePol sameAs SwePol_Link.
- SwePol sameAs m.05k213.
- SwePol sameAs Q59795.
- SwePol sameAs Q59795.
- SwePol sameAs SwePol.
- SwePol lat "54.50211111111111".
- SwePol long "16.891222222222222".
- SwePol wasDerivedFrom SwePol?oldid=593476546.
- SwePol isPrimaryTopicOf SwePol.